Peltier Cooling Calculator

Calculate the expected cooling capacity and efficiency (COP) of a Thermoelectric Cooler.

Actual Cooling Capacity
42.1W
Power Consumption
60.0W
Coefficient of Performance (COP)
0.70

Thermoelectric Cooling (Peltier/TEC) & COP Formula Guide

Thermoelectric coolers transfer heat via the Peltier effect. Cooling capacity (Qc) and Coefficient of Performance (COP) depend on current, voltage, and delta temperature.

1Thermoelectric Equations

Power Consumption (Pin) = Voltage (V) × Current (I)
Coefficient of Performance (COP) = Cooling Capacity (Qc) ÷ Power Input (Pin)

Frequently Asked Questions

Peltier COP usually ranges between 0.3 and 0.8 depending on delta-T. While less efficient than vapor compression, TECs provide silent solid-state cooling.